基金项目:国家水体污染控制与治理重大专项;城市供水水质保障及管网安全运行优化调度技术研究应用
作者单位E-mail
刘雅亭 安徽建筑大学 1298338970@qq.com 
黄显怀* 安徽建筑大学 2770226757@qq.com 
杨伟伟 安徽建筑大学  
宋纲 合肥市供水集团  
朱波 合肥市供水集团  
摘要点击次数: 1124
全文下载次数: 347
中文摘要:
      节点流量作为供水管网建模的重要参数,其分配结果直接影响供水模型准确性。针对目前常规节点流量分配方法准确性不足及工作强度大的问题,提出了基于分区计量系统的供水管网节点流量分配方法。该分配方法中的节点流量是居民用户节点流量、其他工商户节点流量和产销差节点流量之和。居民节点流量通过DMA边界五级表数据确定;其他工商户节点流量通过终端六级远传表数据确定;流量产销差节点流量,以二级分区为单位,在区域内沿线均分后折算至节点流量。该方法运用于H市供水管网水力建模项目,模型校核结果:测压点水压的实测记录值与模拟值之差100%≤±4mH2O;85.83%≤±2mH2O;55.18%≤±1mH2O;23.15%≤±0.5mH2O,满足精度要求,取得良好效果。
英文摘要:
      As an important parameter of water supply network modeling,node-flow directly affects the accuracy of water supply model.Aiming at the problems of insufficient accuracy and high work intensity of the current conventional node-flow distribution methods,this paper proposes a node-flow distribution method of water supply network based on district metering system.The node-flow in this distribution method is the sum of resident user node flow, other industrial and commercial node flow and the no-revenue water node flow.The flow of residential nodes is determined by the five-level water meter at the DMA boundary ; The node flow of other industrial and commercial households is determined by the terminal six-level remote water meter; The no-revenue water node flow is converted into the node-flow after being evenly distributed along the line in each Secondary zoning area.This method is applied to the hydraulic modeling project of water supply network in H city.The model verification results are as follows: the difference between the measured recorded value and the simulated value of water pressure at the pressure measuring point is 100%≤±4mH2O; 85.83%≤±2mH2O; 55.18%≤±1mH2O; 23.15%≤±0.5mH2O, meeting the accuracy requirements,good results were obtained.
查看全文   查看/发表评论  下载PDF阅读器
关闭

分享按钮